EJOT® VHT E 4.8

Specification

  • Applications

    • To fix roofing membrane to substructures made of sheet steel ≥ 0.5 mm ≤ 0.75 mm, timber and wood-based material
    • New buildings and renovations
    • For combination with EJOT® stress plates
    • For thicker and/or two-ply sheet steel we recommend use of the EJOT Dabo® screw TKE-4.8.
  • Properties

    • A4 stainless steel with hardened steel drill point
    • Thread length 100 mm
    • Can be delivered belted for EJOT® ECOSET installation tool or pre-assembled with EJOT® stress plates HTK for EJOT® ECOSET HTK installation tool.
    • With bugle head
  • Technical specifications

    • Diameter: 4.8 mm
    • Drilling capacity: 0.75 mm
    • Drive: Cross recess PH 2

    Length determination (min. lengths)

    • Sheet steel: Insulation thickness + 20 mm
    • Timber: Insulation thickness + 30 mm